Selecting the correct positive displacement pump requires a disciplined approach to gathering and evaluating application data. The STAMPED framework — Size, Temperature, Application & Alloy, Media, Pressure, End Connections, and Dynamics — helps teams ask the right questions up front, so they can better understand what the pump needs to do and how it needs to perform.
When teams apply STAMPED to positive displacement pumps, they evaluate each application consistently, reduce errors, improve quote accuracy, and increase long-term success in the field.
Step 1: SIZE — Define Capacity and Connections
The first step is to determine the required pump size by understanding both the system connections and flow requirements. Identify suction and discharge line sizes, pipe diameters, and required flow rates across minimum, normal, and maximum conditions.
In positive displacement pumps, displacement and speed directly control flow. Establishing the full operating range early helps size the pump properly for the application and avoid issues related to underperformance or oversizing.
Step 2: TEMPERATURE — Understand Thermal Conditions
Next, evaluate the temperature conditions the pump will experience. Some fluids may pump well at room temperature, but become difficult to move when cold. Review process fluid temperatures at minimum, normal, and maximum conditions, along with ambient conditions and any cleaning processes such as Clean-In-Place (CIP) or Sterilization-In-Place (SIP) cycles.
Temperature directly impacts material selection, seal performance, and internal clearances. If teams fail to account for temperature, they may create conditions that lead to premature wear, seal failures, or operational inefficiencies.
Step 3: APPLICATION & ALLOY — Define the Use Case
The application section identifies where and how the pump will be used. Define the industry, such as food, pharmaceutical, or chemical, along with the specific duty, such as transfer, dosing, circulation, or unloading. Also document any regulatory or sanitary requirements.
Use this step to define material selection as well, including wetted materials, such as 316L stainless steel, and elastomers. Proper alignment between the application and materials helps support compatibility, compliance, and long-term reliability.
Step 4: MEDIA — Characterize the Fluid
The media section focuses on the characteristics of the fluid being pumped. Capture viscosity, solids content, particle size, shear sensitivity, abrasiveness, corrosiveness, density, and the presence of air.
Positive displacement pump selection depends primarily on how the fluid behaves. Variations in viscosity or solids can dramatically impact performance, internal slip, and wear. Capturing these details helps teams select the correct pump style and internal configuration.
Step 5: PRESSURE — Define System Demands
The pressure step evaluates the hydraulic requirements of the system. Define suction pressure, Net Positive Suction Head (NPSH) available, discharge pressure, differential pressure, and system pressure limits.
PD pumps generate flow by displacement and will continue building pressure until something relieves that pressure. For that reason, teams must understand pressure requirements not only to achieve performance, but also to protect the pump and system components.
Step 6: END CONNECTIONS — Ensure System Compatibility
The end connections define how the pump interfaces with the piping system. Specify the connection type, such as tri-clamp, flanged, or threaded, along with size, pressure rating, and orientation.
Defining these details properly helps maintain compatibility with the system and prevents costly modifications during installation.
Step 7: DYNAMICS — Evaluate Operation and Behavior
The dynamics section addresses how the pump operates over time. Evaluate pump speed, control method, such as Variable Frequency Drive (VFD), duty cycle, and mechanical concerns like vibration, pulsation, or cavitation.
Also review maintenance expectations, cleaning requirements, and environmental considerations such as washdown or hazardous locations. This step helps confirm that the pump will perform reliably in real-world operating conditions.
Beyond the Pump
STAMPED provides a tried-and-true framework for evaluating positive displacement pumps. But what about the infrastructure that supports the pump?
In Part Two of this blog, we’ll discuss the final step in positive displacement pump evaluation: the Equipment & Accessories step, or “E2.”
By combining STAMPED with the additional E2 step and a clear understanding of why each section matters, teams can confidently move from discovery to selection.
Mark Wheaton | Technical Inside Sales Representative
Mark Wheaton has been with Galloup for 38 years. For the past 25+ years he has focused exclusively on supporting customers in the Food & Beverage, Dairy and Pharmaceutical industries, specializing in high-purity, sanitary process products and solutions. He serves as a senior resource within Galloup’s Process Equipment Division (PED).